APF Active Power Filter Cabinet
APF Active Power Filter Cabinet
APF Active Power Filter Cabinet
APF Active Power Filter Cabinet
APF Active Power Filter Cabinet
APF Active Power Filter Cabinet
APF Active Power Filter Cabinet
Product details
Product Introduction
Product Introduction
This is a new type of power harmonic mitigation equipment developed using a parallel connection method (current-mode), modern power electronics technology, and digital signal processing technology based on high-speed DSP devices.
By real-time monitoring the load current, the analog current signal is converted into a digital signal via high-precision, high-performance A/D conversion. This digital signal is then sent to a high-speed digital signal processor (DSP) for processing, which separates the harmonics from the load current to form a command signal. The command signal is sent as a pulse-width modulation (PWM) signal to the converter (compensation current generation circuit) to issue a driving instruction. The converter absorbs the positive harmonic current, charges the high-voltage capacitor on the DC side with the absorbed energy, and then releases this energy in a waveform with an opposite phase to the negative harmonics to offset the negative harmonics.

Technical features:
● Real-time following and dynamic compensation
It adopts harmonic current detection technology based on instantaneous reactive power theory to detect harmonic current in real time; through instantaneous current tracking control, it can realize dynamic compensation of harmonic current and automatically track the harmonic changes of the power grid, which is highly controllable and fast responsive.
● Flexible compensation methods
One machine has multiple functions. It can not only control harmonics, but also compensate reactive power and improve power factor. It can independently compensate a single harmonic source or collectively compensate multiple harmonic sources. It can also achieve harmonic control. Designate harmonics for treatment; can be used as a harmonic source.
● DSP intelligent monitoring
DSP high-speed detection and calculation ensures accurate and effective harmonic detection and compensation control; it also has intelligent monitoring functions, flexible device control, and clear operating parameters and working status; automatic fault diagnosis; with remote communication interface, real-time monitoring through PC.
●Advanced power conversion design
It adopts the latest IGBT high-frequency switching device, and the main circuit topology is a three-phase bridge type fully controlled PWM converter, which has the characteristics of small size, high efficiency and high reliability. Advanced multiplexing technology enables expansion of the overall machine capacity.
●Standard modular design
The power circuit and control circuit adopt a modular structure, which improves reliability and maintainability in use while achieving standardized production.

Suggested applications for active filters:
● If the harmonics are serious (>50%), only tuned passive filters or active filters can be used to control harmonics.
● The background harmonics are large, and the tuned filter is in danger of resonance or overload.
● If the power factor is high, the tuned filter will overcompensate, and the automatic switching device for reactive power compensation cannot be put into use, such as a frequency converter.
● High-order harmonics are serious and require high filtering effect.
● A new harmonic source needs to be installed and the capacity needs to be expanded.
● Neutral line harmonic elimination (3rd harmonic)—4-wire active filter
● Fast phase-separated reactive power compensation, thyristor switching speed cannot meet the requirements

Technical Parameters:
Technical Parameters
Operating Voltage
380V/690V ±20% 50/60Hz
Compensation current
25A~300A
Filter effect
THDI<5%
Response time
All or selected harmonics from 2 to 60 times
Overload protection
<20ms
On-off level
Output current is limited to 100%
Display operation interface
20KHz
Indicator lightMulti-line Chinese character interface
Signal output
Operation, alarm, failure
Remote monitoring
Relay output
Installation method
RS485
Operating environment temperature
Single machine operation or no more than 10 units in parallel operation
Storage temperature0~40℃
Relative humidity
-40℃~65℃
Altitude
<1000m
Protection level
IP20 (or according to customer needs)