GGJ Low-Voltage Reactive Power Intelligent Compensation Device
GGJ Low-Voltage Reactive Power Intelligent Compensation Device
Product details
Product Introduction
Product Overview
The GGJ Low-Voltage Reactive Power Intelligent Compensation Device can effectively improve the power factor of electrical loads, reduce line losses, and enhance the actual load-carrying capacity of transformers, delivering significant energy-saving effects. Meanwhile, by adopting specific reactors in the system, it can also effectively prevent harmonic amplification and absorb most harmonic currents, ensuring that the total harmonic voltage distortion limit and the harmonic current content limit of each order comply with national standards, thus achieving the goal of harmonic mitigation.
This device incorporates a microcomputer control system to implement intelligent tracking and compensation of reactive power. It features a reasonable structure and advanced technology, making it suitable for low-voltage power grids such as substations, production workshops of industrial and mining enterprises, and civil buildings. It is particularly well-suited for power transmission and distribution systems where loads change frequently and reactive power is unstable.
It plays a significant role in improving the power factor, reducing reactive power losses, and enhancing power supply quality, and is therefore a new generation of energy-saving products.
Model and Its Meanin













Main Features
1、Controlled by an intelligent controller, it has complete functions, reliable performance, and an automatic compensation mode; it can increase the power factor to above 0.9.
2、Real-time display of power grid power factor, with a display range: lagging (0.00-0.99), leading (0.00-0.99).
3、Equipped with multiple comprehensive protection functions, including overvoltage, over-harmonic, over-compensation, system fault, phase loss, and overload protection.
4、Remembers the set parameters; parameters will not be lost after a system power outage. After the power grid returns to normal, it automatically enters the operating state without the need for personnel on duty.
5、Can adopt phase-separated compensation or mixed compensation according to the power grid load balance status.
6、Strong anti-interference capability: it can withstand interference pulses with an amplitude of 2000V directly input from the power grid, which is higher than the national professional standards.
Technical Parameters of GGJ
Item
Parameter
Rated Voltage
0.38-0.66kV
Rated Frequency
50Hz
Rated Capacity
1-600kvar
Applicable Voltage Range
(0.85-1.1) times the rated voltage
Maximum Allowable Current
1.3 times the rated current
Control Circuit
1-16 circuits
Switching Time
1-150s per operation, adjustable
Operating Mode
Automatic, continuous operation
Main Functions
1、Real-time measurement and on-the-hour recording of three-phase voltage, current, frequency, active power, reactive power, power factor, active energy, and reactive energy on the low-voltage side of the transformer; total harmonic distortion (THD) of voltage and current, and harmonic content of the 2nd to 25th orders.
2、Equipped with RS-232 and RS-485 interfaces, it supports data logging via a handheld computer and enables wireless meter reading through remote communication functions. It also allows device testing, parameter setting, and reading of real-time measurement data and recorded data.
3、Data analysis function: It can analyze, process, statistically query the operating load data; comprehensively analyze power supply quality, calculate voltage qualification rate, power supply load rate, reliability rate, and maximum load rate; query power factor, active power, and reactive power by time period; draw curves of phase voltage, current, power factor, etc.; and print comprehensive analysis results and statistics.

Contact

Leave your information and we will contact you.

Customer services

Contact us

Email: 715099793@qq.com

Tel: 13559343866

TEL
QQ